-40%

VFD Variable Frequency Drive 1.5KW VFD 1 to 3 Phase Converter 220V 2PH VSD

$ 40.65

Availability: 56 in stock
  • Input Voltage: 220V
  • Condition: New
  • Rated Load: 2HP
  • Power Rating: 1500W
  • Number Of Phases: 3-Phase
  • Brand: CNSWIPOWER

    Description

    Rated Parameters
    MODEL
    Nominal Capacity
    (KVA)
    Input Current
    (A)
    Output Current
    (A)
    Applicable Motor Output
    (KW)
    Applicable Motor Output
    (HP)
    Overall Dimension
    (MM)
    Installation Dimension
    (MM)
    1.5KW
    3
    14
    7
    1.5
    2
    170*85*139
    158*68
    Specifications
    Functional
    Descriptions
    Specifications
    INPUT
    Input Voltage
    AC,1 to 3 Phase,220V(-15%) ~ 240V(+10%)
    ated Frequency
    50/60 Hz
    Frequency Range
    ± 5% (47.5 ~ 63Hz)
    OUTPUT
    Output Voltage
    0- Input Voltage
    Maximum Output
    Frequency
    0.1 ~ 500HZ
    Output Power
    Please refer to Rated Parameter table
    Output Current
    Please refer to Rated Parameter table
    BASIC PARAMETERS
    Highest frequency
    Vector control: 0~500Hz
    V/F control:0~500Hz
    Carrier frequency
    0.8KHz~8KHz(Support up to 16KHz carrier frequency)
    Adjusted automatically according to the load characteristics
    Input frequency resolution
    Digital setting: 0.01Hz
    Analog setting: Highest frequency× 0.025%
    Control mode
    Open-loop vector control (SVC)
    V/F control
    Starting torque
    0.5Hz/150% (SVC)
    Adjustable speed ratio
    1:100 (SVC)
    Speed control accuracy
    ± 0.5% (SVC)
    Overload capability
    150% of rated current: 60 seconds
    170% of rated current: 12 seconds
    190% of rated current: 1.5 seconds
    Torque boost
    Auto torque boost; Range of manual torque boost 0.1%~30.0%
    V/F curve
    Three types: Linear, Multi-point, square curve (1.2 power, 1.4 power, 1.6 power, 1.8 power, 2 power)
    V/F separation
    Full separation, Half separation
    Acceleration and deceleration time
    Linear and S-curve acceleration and deceleration modes available. The range of acceleration and deceleration time is 0.0~6500.0s.
    DC braking
    DC braking frequency: 0.00Hz ~ Maximum frequency
    Braking time: 0.0s~36.0s
    Braking current value: 0.0%~100.0%
    JOG control
    JOG frequency range: 0.00Hz ~ Maximum frequency (5Hz in default).
    JOG acceleration and deceleration time: 0.0s~6500.0s.
    Built-in PID
    Simplify the establishment of a closed-loop control system
    Automatic voltage regulation (AVR)
    Keep the output voltage in stable when the grid voltage fluctuates.
    Stall prevention from overvoltage and
    overcurrent
    The current and voltage are limited automatically during operation to prevent frequent tripping due to over-current and over-voltage.
    Rapid current limit
    Reduce the risk of over-current faults to keep VFD operated normally.
    Torque limit and control
    Limit the torque automatically during operation to prevent frequent tripping
    due to over-current.
    Braking unit
    Built-in braking unit for 18.5KW and below models
    SPECIAL FEATURES
    Deceleration to stop
    In case of power loss, the energy from load feedback is used to compensate and decelerate the motor until standstill, to prevent mechanical damage.
    Rapid current limit
    Reduce the risk of over-current faults to keep VFD operated normally.
    Timer control
    Setting range: 0.0Min ~ 6500.0Min
    Communication
    Modbus
    INPUT & OUTPUT
    Command source
    Operation panel, control terminal and serial communication port.
    Frequency source
    Digital setting, Analog voltage setting, Analog current setting, Pulse setting and Serial port setting.
    Auxiliary frequency source
    5 options to provide flexible auxiliary frequency fine-tuning and frequency synthesis.
    Input terminals
    4 digital input terminals, one of which supports high-frequency pulse input up to 50kHz
    Output terminals
    1 analog input terminal supporting 0 ~ 10V voltage input or 0 ~ 20mA
    current input
    DISPLAY BUTTONS
    LED display
    Display parameters
    Key lock and function selection
    It allows users to partially or fully lock the keys or define operated range for partial keys to prevent misoperation
    Protective function
    Motor short-circuit detection at power-on, output phase loss protection, over-current protection, over-voltage protection, under-voltage protection, overheat protection, overload protection and etc.
    ENVIRONMENT
    Storage temperature
    -20°C ~ 60°C
    Operation temperature
    -10°C ~ 50°C (If temperarture is higher than 40°C, the output capacity will be derated 1% per 1°C increase)
    Storage humidity
    <90%RH
    Operation humidity
    <90%RH
    Noise Level
    50dBA max.
    OTHERS
    EMC
    Standards:
    IEC 61800-3, C3
    Safety
    Standards:
    IEC 61800-5-1
    INTERACE
    Communication Port
    RS-485