-40%
VFD Variable Frequency Drive 1.5KW VFD 1 to 3 Phase Converter 220V 2PH VSD
$ 40.65
- Description
- Size Guide
Description
Rated ParametersMODEL
Nominal Capacity
(KVA)
Input Current
(A)
Output Current
(A)
Applicable Motor Output
(KW)
Applicable Motor Output
(HP)
Overall Dimension
(MM)
Installation Dimension
(MM)
1.5KW
3
14
7
1.5
2
170*85*139
158*68
Specifications
Functional
Descriptions
Specifications
INPUT
Input Voltage
AC,1 to 3 Phase,220V(-15%) ~ 240V(+10%)
ated Frequency
50/60 Hz
Frequency Range
± 5% (47.5 ~ 63Hz)
OUTPUT
Output Voltage
0- Input Voltage
Maximum Output
Frequency
0.1 ~ 500HZ
Output Power
Please refer to Rated Parameter table
Output Current
Please refer to Rated Parameter table
BASIC PARAMETERS
Highest frequency
Vector control: 0~500Hz
V/F control:0~500Hz
Carrier frequency
0.8KHz~8KHz(Support up to 16KHz carrier frequency)
Adjusted automatically according to the load characteristics
Input frequency resolution
Digital setting: 0.01Hz
Analog setting: Highest frequency× 0.025%
Control mode
Open-loop vector control (SVC)
V/F control
Starting torque
0.5Hz/150% (SVC)
Adjustable speed ratio
1:100 (SVC)
Speed control accuracy
± 0.5% (SVC)
Overload capability
150% of rated current: 60 seconds
170% of rated current: 12 seconds
190% of rated current: 1.5 seconds
Torque boost
Auto torque boost; Range of manual torque boost 0.1%~30.0%
V/F curve
Three types: Linear, Multi-point, square curve (1.2 power, 1.4 power, 1.6 power, 1.8 power, 2 power)
V/F separation
Full separation, Half separation
Acceleration and deceleration time
Linear and S-curve acceleration and deceleration modes available. The range of acceleration and deceleration time is 0.0~6500.0s.
DC braking
DC braking frequency: 0.00Hz ~ Maximum frequency
Braking time: 0.0s~36.0s
Braking current value: 0.0%~100.0%
JOG control
JOG frequency range: 0.00Hz ~ Maximum frequency (5Hz in default).
JOG acceleration and deceleration time: 0.0s~6500.0s.
Built-in PID
Simplify the establishment of a closed-loop control system
Automatic voltage regulation (AVR)
Keep the output voltage in stable when the grid voltage fluctuates.
Stall prevention from overvoltage and
overcurrent
The current and voltage are limited automatically during operation to prevent frequent tripping due to over-current and over-voltage.
Rapid current limit
Reduce the risk of over-current faults to keep VFD operated normally.
Torque limit and control
Limit the torque automatically during operation to prevent frequent tripping
due to over-current.
Braking unit
Built-in braking unit for 18.5KW and below models
SPECIAL FEATURES
Deceleration to stop
In case of power loss, the energy from load feedback is used to compensate and decelerate the motor until standstill, to prevent mechanical damage.
Rapid current limit
Reduce the risk of over-current faults to keep VFD operated normally.
Timer control
Setting range: 0.0Min ~ 6500.0Min
Communication
Modbus
INPUT & OUTPUT
Command source
Operation panel, control terminal and serial communication port.
Frequency source
Digital setting, Analog voltage setting, Analog current setting, Pulse setting and Serial port setting.
Auxiliary frequency source
5 options to provide flexible auxiliary frequency fine-tuning and frequency synthesis.
Input terminals
4 digital input terminals, one of which supports high-frequency pulse input up to 50kHz
Output terminals
1 analog input terminal supporting 0 ~ 10V voltage input or 0 ~ 20mA
current input
DISPLAY BUTTONS
LED display
Display parameters
Key lock and function selection
It allows users to partially or fully lock the keys or define operated range for partial keys to prevent misoperation
Protective function
Motor short-circuit detection at power-on, output phase loss protection, over-current protection, over-voltage protection, under-voltage protection, overheat protection, overload protection and etc.
ENVIRONMENT
Storage temperature
-20°C ~ 60°C
Operation temperature
-10°C ~ 50°C (If temperarture is higher than 40°C, the output capacity will be derated 1% per 1°C increase)
Storage humidity
<90%RH
Operation humidity
<90%RH
Noise Level
50dBA max.
OTHERS
EMC
Standards:
IEC 61800-3, C3
Safety
Standards:
IEC 61800-5-1
INTERACE
Communication Port
RS-485