-40%
Variable Frequency Drive MYSWEETY VFD Inverter Frequency Converter 2.2KW 3HP ...
$ 105.59
- Description
- Size Guide
Description
Package include:1 x 1.5kw / 2.2kw 220v Inverter
(The inverter is single-phase 220V input, three-phase 220V output)
1 x Inverter Manual
Tech parameters:
Type
1.5KW 220V
2.2KW 220V
Output current
7A
10A
Power
1.5KW
2.2KW
Input voltage
220V
220V
Drive capacity
2.8KVA
4.0KVA
Using motor
1.5KW
2.2KW
Weight
1.5KG
1.5KG
Product Size
170*125*163
170*125*163
Package Size
235*195*230
235*195*230
Note: Please read the instructions carefully before use.
This inverter needs
150 ohm 200W
braking resistor,i
f you want a brake resistor, please click on the picture to purchase:
Advantage:
Control mode is SPWM, very easy to use and convenient
Protection functions are very strong
Fin over-heat protection
Overload protection
Fuse protection
Restart after instant stop, stall protection
Powerful function
Manual download
(We only have English Manual)
https://my.pcloud.com/publink/show?code=XZl1EjkZScfaSxtNo37cUaPfLfn1GLo0xo9X
About inverter commissioning manual:
https://u.pcloud.link/publink/show?code=XZggE8XZ576Vd9ovvoR5mJ2l3R9824bi0ytV
If you are unable to download from the above link, please contact me and provide us your email , we will send the manual to you
How to judge whether the inverter is good or bad?
1. Restore the factory setting P00.13 to 10, restart the inverter after the light goes out after power-off, remove the connecting motor and ground wire, and run the inverter with no load if the RUN light is always on and there is no fault code. It means that there is no problem with the inverter.
2. If an error code appears after connecting the motor, it may be that the motor is broken; or there is a problem with the wiring
Note: Please read the instructions carefully before use.
For YL600 inverter, our parameters are set to 50HZ by default.
If your motor needs to rotate at high speed, such as a 400HZ spindle motor, you should set the inverter parameters as follows: P00.00 = 400HZ, P00.04 = 400HZ, P00.05 = 400HZ, P00.07 = 40HZ, P00.08=10.0HZ,P00.09 = 4.0HZ, P03.09 = 400HZ, P03.13 = 400HZ, P03.17 = 400HZ.
If you directly restore the factory settings, the inverter can be used with 50HZ motors.
Any problems ,please feel free contact me.