-40%
STEPPERONLINE VFD 7.5KW 10HP 3 Phase Variable Frequency Drive Inverter 220V
$ 112.46
- Description
- Size Guide
Description
This VFD with power 10HP(7.5KW) and three phase 220V input voltage. The H100 series is General Variable Frequency Drive(VFD), they are widely used in application of: Textile machines, Packaging machines, Engraving machines, Printing machines, Food machinery, Woodworking machinery, Pump fans, Ceramic machinery, Solar pumps and others.Package Content
1 x 7.5KW Variable Frequency Drive Inverter
1 x English Manual
Key Specification
Rated Input Voltage: 3-Phase 220V
Allowed Input Voltage: 320~460VAC
Input Frequency: 50/60Hz(+/-5%)
Input Current: 37A
Power: 10HP(7.5KW)
Output Current: 31A
Output Voltage: 0~Rated Input Voltage
Output Frequency: 0~1000Hz
Output Capacity: 150% Rated Current 60s, 180% Rated Current 2s
Peripheral device connection
Main circuit and function card
Power terminal wiring instructions
For 220V class inverter, use class 3 grounding method(grounding resistance: less than 100Ω).
Use special grounding terminal for grounding. Do not use screws for grounding in the box.
Note: Grounding steps
(1) Determine the location of the ground terminal.
(2) Connect the ground-wire to the ground terminal and make sure that the screws are tight
Main circuit terminal description
Please implement the wiring in accordance with the regulations of electrician regulations to ensure safety
When selection of the wire diameter specification
● It is best to use isolated wires or conduits for power wiring, and ground the isolation layer or conduits at both ends.
● Be sure to install the air disconnect switch NFB between the power supply and the input terminals(R / L1, S / L2, T / L2)
● Do not connect the AC power supply to the output terminal (U V W) of the inverter.
● The output wiring must not touch the metal shell of the inverter, in case of a short circuit to ground.
● Do not use phase shift capacitors, LC / RC noise filters and other components at the output of the inverter.
● The main circuit wiring of the inverter must be far away from other control equipment.
● When the wiring between the inverter and the motor exceeds 15 meters (220V level),(380V level 30 meters), a high dV / dT will be generated inside the motor coil, which will produce interlayer insulation of the motor then damaged, please use a special motor for the inverter or install a reactor on the inverter side.
Keyboard Features
On Oct 27, 2022 at 19:01:41 PDT, seller added the following information: