-40%

Single phase 220V 7.5KW 10HP 1000HZ VFD Inverter for CNC engraving spindle

$ 188.49

Availability: 20 in stock

Description

7.5kw 10HP 1000HZ best VFD Inverter Frequency converter single phase 220v input 3phase 0-220v output 33A for Engraving spindle motor
VFD Brand
BEST
VFD Model
FC300-7.5G-S2
Input voltage
Single phase 220V
Output voltage
Three phase 0-220V
Rated power
7.5kw 10HP
Rated output current
33A
Input frequency
50HZ-60HZ
Output frequency
0-1000hz
If you need the user manual English version or the video of setting parameters, please contact me and ask for it
Single phase 220V Class
Power(kW)
0.75
1.5
2.2
3.0
3.7
5.5
7.5
11
15
18.5
Applicable Motor(kW)
0.75
1.5
2.2
3.0
3.7
5.5
7.5
11
15
18.5
Input Rating
Current(A)
7.5
11
16
22
27
36
49
73
96
111
Voltage(V)
Single Phase 220V
Frequency(HZ)
50/60Hz
Output Rating
Current(A)
5
7
11
15
18
25
33
49
65
75
Voltage(V)
Three phase 0~220V
Frequency(Hz)
0~1000Hz
Overload protection
200% over current immediately
150% 1 minute
Three phase 380V Class
Power(kW)
0.75
1.5
2.2
3.0
3.7
5.5
7.5
11
15
18.5
Applicable Motor(kW)
0.75
1.5
2.2
3.0
3.7
5.5
7.5
11
15
18.5
Input Rating
Current(A)
4.0
6.3
8.2
12
14.5
19
25
33
46
52
Voltage(V)
3ph 380V
Frequency(HZ)
50/60HZ
Output Rating
Current(A)
2.7
4.2
5.5
8.0
9.5
13
18
24
32
38
Voltage(V)
3ph 0~380V
Frequency(Hz)
0~1000Hz
Overload protection
200% over current immediately
150% 1 minute
Frequency control
1.Range: 0.0~1000.00Hz
2.Other functions: Lower limit frequency, start frequency, frequency of parking, three jumping frequency can be set respectively
3.Precision: Digital: 0.01% (10~40
centigrade degree
); Analog: 0.1% (25±10 centigrade degree)
4.Keyboard set way: 0.01 Hz can be directly to setting by up and down.
5. Analog set way: external voltage 0 to 5V, 0 to 10 V, 4-20 mA, 0 to 20 mA
Connecting mode
1. L  N connect to single phase 220V voltage(part of zero line and live line).while R S T to three phase voltage.
2. U  V  W connect to spindle motor. The 1,2,3 pin of spindle motor plug connect converter U,V,W. That is: 1- U,2-v,3-w,4 is ground wire. If spindle motor rotated reverse, Please send any two thread swap places
3.Control com is comcon terminal ,X2 low speed ,X3 middle speed ,X4 high speed(for NCStudio card,DSP or Analog control mode)
Adjust converter parameters
1. external terminal control :Press cancel button:P000 turn into P087, confirm -0- turn into 101,display H0.0
2.Turn into manual control: press cancel button, P000 turn into p065,confirm that is 0,display P064,then press cancel button ,display H0.0, Rotate knob to H400.0(when the spindle is 400hz) or other, converter display a number multiply by 60,the results is the rotating speed. Press the operation or stop then ok.
Parameter Settings refer to the pictures