Huanyang VFD 220V 4.0kw 5HP Variable Frequency Drive Inverter Convert for Motor
$ 71.72
- Description
- Size Guide
Description
IMPORTANT NOTEThe vfd can only drive
three-phase asynchronous motors
and
cannot be used as a power source.
If your motor is
heavy load
, pls choose a
higher horsepower vfd
than your motor's
To protect the VFD, be sure to
press the red button "Stop" and turn off
the power when you stop using it.
220v-4.0kw(5HP) VFD Specifications
Applicable motor horse-power
≤ 3kw(4HP)
Input valtage
220VAC(+/-5%) 1 or 3 phase(”R“,”T“ terminals for 1 phase,”R“,”S“.”T“ terminals for 3 phase)
output valtage
3 phase 220v
input Frequency
47-63Hz
output frequency
0-400Hz, 0-50Hz/60Hz
rated current
16A (Represents the maximum current the VFD can withstand,this is a fixed value)
Circuit breaker suggestion
40A
Wire specification suggestion
13 AWG
Function introduction
DC cooling fan
DC cooling fan low noise, large air volume help vfd heat dissipation, improve product stability
basic parameter for 400hz spindle
For
400hz
motor:Set
pd005=400,pd004=400,pd003=400,pd072=400,pd144=3000
,Then you can start driving the 400hz spindle.
(Note:The VFD is
already set to 400Hz by default when it is received
)
basic parameter for 3 phase 50/60Hz motor
Drive
50/60hz motor
:Set
pd005
=50/60,
pd004
=50/60,
pd003
=50/60,
pd072
=50/60
Diverse terminals, more functions for you to choose.
Unlike other inexpensive VFDS, this VFD has two sets of terminal functions,Rich of digital and analogy control terminals for versitile control,optional MODBUS (RS485) extension,diversified parameter setting.
supports external potentiometer control
(connect the "FOR" and "DCM" terminals,than set PD001=1)
supports mcah3 function and RS-485 communication
(For more information, you can contact the seller, we will send you a video of the basic functions of VFD)
Multi-function panel keyboard
UP
: Progressively increase data or function codes.
DOWN
: Progressively decrease data or function codes.
SET
: Enter menus step-by-step, save setting parameters.
PRGM
: Exit current(or present) state, switch among each states, mainly used to switch monitoring state, exit to previous menu.
FWD/REV
: 1, Press momentary button to start,release to stop; 2 Switch the rotation direction
SHIFT
: Switch monitoring parameters at monitoring state, at secondary menu, move data box to process editing position.
Kindly Note
: If you want to show RPM in the display,please press 'SHIFT' key
Advanced motherboard features
PID control; advanced calculus PID closed-loop arithmetic, quick responding speed and high suitability
Easy PLC function can realize 16 legs of speed and inverter control function
RS485 communication port, adopting standard international MODBUS main circuit control
With extremely strong anti-jamming capability
Low output ratting torque0.5HZ-150%, low speed running ability
Carrier adjustable by 16KHZ, completely soundless working environment
Broad voltage working area, normal running in 304V-456V
Auto voltage regulation (AVR) technique, for ensuring the inverter load capability
With perfect error protection and short circuit starting protection capability